ENGINEERING SPECIFICATIONS:  StarTOC ON-LINE UV/Heated Persulfate TOC
                 
                 
                 
Model/Name StarTOC ON-LINE UV Heated Persulfate Analyzer Notes
Analysis Method UV heated Persulfate/Non-Dispersive Infrared (NDIR) CO2 Detection  
Analytes Measured Total Organic Carbon; Total Carbon; Total Inorganic Carbon; Non-Purgeable Organic Carbon; TOC-True (including purgeable Organics)  
Detector Type (CO2) NDIR (solid state; no moving parts; computer-controlled; non-reflective sample cell-impervious to corrosion and guaranteed for 5 years) Footnote 1 - NDIR vs Conductivity
Control/Data Handling Industrial Microsoft Windows CE Computer, Touch Screen, Paperless Chart Recorder    
 
Sample Introduction Continuous Pumps or Digital Injection (Pumpless)  User to specify choice
                 
Sample Handling Up to 1000 Microns Suspended Solids      
Measurement Specifications    
       
Measurement Range (mg/L) 0-10 thru 0-1000 (w/o dilution)  
0-25,000 (with automatic on-board dilution)    
       
Accuracy/Repeatability (%) 2    
       
Carrier Gas Flow (mL/min.) 300 mL/max - Computer Controlled Mass Flow Controller     
CO2 & HC - FREE AIR, OR O2     
  15 +/- 2 PSI    
Average Analysis/Response Time (minutes) including TIC 7    
       
Outputs RS-232    
  RS-485    
  4-20 mA  (2 ea.)    
  Alarm Relays (3)    
       2 Level Alarms    
       1 Malfunction Alarm    
  Loss of Carrier    
  Out of Service Signal (when unit in calibration or validation check)    
       
Display Flat Panel Color Paperless Chart Recorder    
                 
Data Storage Internal Memory    
                 
Sample Requirements              
       
Temperature Range 4 - 90C   TOC Systems offers cooler for
  40 - 194F   higher temperatures
       
         
Sample flow rate  20 mL/min   Fast by-pass loop suggested
       
Inlet pressure  0-5 psi    
                 
Sample Drain gravity/air break    
                 
UTILITIES Required      
                 
Power:   100/200 VAC    
    50/60 HZ.        
    15 Amp Service        
                 
Carrier Gas CO2 & HC - free air or O2 (300 mL/minute-max.);     
  15 +/- 2 PSI        
           
Reagents Prepackaged Sodium Persulfate    
  Phosphoric Acid    
  Calibration Standards    
  D.I. Water    
                 
Environment Operating Temperature: 10 - 50C    
                                            50 - 122F    
       
Construction      
  Enclosure      
    Epoxy Powder Coated cold rolled Steel      
    Stainless Steel (option)      
                 
  Dimensions (HXWXD) 51 X 51 X 38 (cm)    
  20 x 20 x 15 (in)    
       
  Mounting  Rack or Wall Mount    
                 
  Weight 34 Kg    
  75 Lbs    
       
Area Classification Option NEMA - 4, IP 65 Enclosure    
       
Compliance/Certification CE, CSA, ASTM, EPA Methods    
                 
Conformity Complying with all International Standards, such      
    as: DIN-EN 1484, DIN-ENV 12260, DIN 38409-H3,     
    ISO 8245, Standard Method 5310B, Standard       
    Method 5310C, Standard Method 5310D, USEPA      
  415, USEPA 9060, ASTM D5173, EN 13137      
                 
General Features Auto-Calibration,         
    Auto-Validation,           
    Auto-Cleaning,          
    Historical Data/Time and Date Stamped      
                 
Options        
    Multi-Stream Analysis      User to specify number of streams
             
                 
    Oxygen Generator (electricity only)   Eliminates Gas Bottles for up to 5 analyzers.  Plant Air Not Required. (For indoor/climate controlled environments only)
             
             
             
             
    TOC Systems also offers custom options.      
               
(All performance specifications have been verified in a controlled laboratory environment.  Actual field performance 
may vary with application measuring range and detection limits depend on the method, injection volume, vessel purity, 
chemicals and gases used, and the qualification of the operators.)
 
Footnote 1              
          Conductivity vs. NDIR Interferences Chart
               
          Reliability of TOC Results in ULTRAPURE WATER ANALYSIS